Flush Diaphragm Pressure Transmitter for Hygienic Applications – XCL-YB-16S
Xi’an Famous Electric Co., Ltd.
Certifications


All products are EU and ISO certified

Sensor Model: XCL-YB-16S
Technical Specifications
Parameter | Specification |
---|---|
Measuring Range | 0–250 MPa |
Overall Accuracy | ±0.25% FS (also available: ±0.5%, ±1.0%, ±1.5%, ±2.0% FS) |
Protection Level | IP67 |
Output Signal | 0–5V DC; 0.5–4.5V DC (3-wire voltage type); 4–20mA (2-wire current type) |
Power Supply | DC 18–30V |
Category | Pressure Sensors |
Material | Metal and Plastic |
Customization | Accept customization |
Pictures

Sensor Picture:XCL-YB-16S
Key Features
✅ Non-Clogging Design
Flat diaphragm flush-mounted surface (316L/HASTELLOY® options) prevents media buildup in viscous/slurry applications.
✅ High-Accuracy Measurement
±0.075% FS accuracy with 0-100mPa range, featuring laser-trimmed ASIC temperature compensation (-40°C to +150°C).
✅ Corrosion Resistance
EN 1.4404/C22 stainless steel body with PTFE/PEEK coating options (NACE MR0175 compliant for sour gas).
✅ Harsh Media Compatibility
Sanitary EHEDG-certified design for food/pharma, CIP/SIP washdown capable (IP69K/IP69K rating).
✅ Smart Output Options
4-20mA+HART/RS485/IO-Link interfaces with 16-bit resolution and 50ms response time.
✅ Overload Safety
200% FS burst pressure limit and reverse polarity/EMC protection (IEC 61000-4-4/6 compliant).
Application Scenarios
🟡 Oil & Gas Production
- Wellhead multiphase flow pressure
- Pipeline sludge deposition monitoring
- LNG storage tank vapor pressure control
🟡 Pharmaceutical Processing
- Fermentation bioreactor pressure
- Tablet compression force verification
- Cleanroom HVAC differential monitoring
🟡 Food & Beverage
- High-viscosity sauce filling level
- CIP system filter ΔP measurement
- Bottle carbonation pressure control
🟡 Water Treatment
- Membrane bioreactor TMP sensing
- Sludge dewatering pressurization
- Desalination RO membrane cleaning
🟡 Chemical Processing
- Polymer reactor viscosity-pressure
- Acidic catalyst injection control
- Powder fluidization bed pressure
🟡 Hydrogen Energy
- Fuel cell stack water management
- H₂ storage vessel safety venting
- Electrolyzer stack compression
🟡 Marine Engineering
- Ballast tank pressure balancing
- Dynamic positioning thrust monitoring
- Offshore drilling riser tension
🟡 Medical Devices
- Sterilization autoclave cycle
- Dialysis machine blood circuit
- Ventilator airway pressure feedback
Your Concerns
Delivery
- ✅ Standard Products: 5-7 working days
- ✅ Customized Solutions : 15-20 working days
- ✅ Expedited Service: 3-day
Transportation
- Sea freight
- Air freight
- China-Europe express
Payment
- Western Union
- L/C at Sight
- PayPal
Quality
- 100% Pre-shipment Inspection
- Marine Insurance
- Anti-Static/Shock-Proof Packaging
Documents
Install Video
Description
The XCL-YB-16S is a flush diaphragm pressure transmitter specifically designed for hygienic applications where cleanability and precision are essential. Ideal for food processing, pharmaceuticals, and chemical industries, it delivers reliable performance with corrosion-resistant construction.FAQ – XCL-YB-16S Flush Diaphragm Pressure Transmitter
✅ What is the measuring range of the XCL-YB-16S flush diaphragm pressure transmitter?
The XCL-YB-16S supports a wide measuring range up to 0–250 MPa, with high accuracy levels (±0.25% FS standard, options down to ±0.075% FS) suitable for food, pharmaceutical, and chemical process monitoring.✅ Why use a flush diaphragm design in hygienic pressure transmitters?
The flush diaphragm design prevents clogging and residue buildup, ensuring reliable pressure measurement in viscous or slurry media. It is CIP/SIP compatible, making it ideal for hygienic industries such as food & beverage, dairy, and biopharma.✅ What materials are available for the diaphragm and housing of the XCL-YB-16S?
The transmitter can be made with stainless steel 316L, HASTELLOY®, or EN 1.4404/C22 materials, with PTFE or PEEK coatings for aggressive or corrosive media, ensuring compliance with hygienic and chemical standards.✅ What output signals does the XCL-YB-16S pressure transmitter support?
It offers flexible outputs including 4–20mA (2-wire), 0–5V/0.5–4.5V (3-wire), RS485, HART, and IO-Link, making integration easy with PLC, DCS, and smart factory systems.✅ Can the XCL-YB-16S withstand cleaning and sterilization processes (CIP/SIP)?
Yes. With IP67/IP69K protection and EHEDG-compliant sanitary design, the XCL-YB-16S withstands high-temperature steam sterilization, chemical cleaning, and frequent washdowns required in hygienic environments.✅ What industries commonly use the XCL-YB-16S flush diaphragm pressure transmitter?
It is widely used in food & beverage (sauce filling, carbonation), pharmaceuticals (fermentation, cleanroom HVAC), chemicals (polymer reactors, catalyst injection), water treatment, oil & gas, hydrogen energy, and medical devices such as autoclaves and dialysis machines.✅ Does the XCL-YB-16S have overload and EMC protection?
Yes. It is designed with 200% FS overload safety and meets IEC 61000-4-4/6 EMC standards, ensuring reliable operation even in harsh industrial environments.Contact & Support
Contact Our Engineers
📞 +86-029-86416613-5714 | +86 18092239472 | +86 18192259863
📧 fmssales3@xafms.com | estxs03@xaest.com
📍 Address:Xi 'an Gaoling District Ronghao Industrial City China V3-03